2018 / 10 / 12 Loading...
Fault 1: internal electronic thermal relay protection action error symbol: OL1
Resolvent:
1. check whether the motor is overloaded.
2. check whether the rated current value of the motor is suitable. (7-00)
3. check the function settings of the electronic thermal relay.
4. increase the motor capacity.
Fault two: output current exceeding the current error symbol of motor driver: OL
2. reduce (7-02) torque setting value.
3. increase the output of motor driver.
Fault three: Communication exception error symbol: CE1
1. check whether the communication signal has reverse connection SG+, SG-.
2. check whether the communication format is correct.
Fault four: motor load is too large error symbol: OL2
1. check whether the load of the motor is too large.
2. check the torque setting value (6-03).